Ap-Maldi-uhr

The AP-MALDI-UHR source is the model that is used to generate high resolution images of sections from a variety of sample type such as mammalian organs plant tissues, inorganic surfaces such as metals with organic contaminants. See application area for detailed examples.

Leaders in the design and production of AP-MALDI sources
Leaders in the design and production of AP-MALDI sources
AP-MALDI-UHR

Technical information

Type of ionization
Atmospheric pressure matrix-assisted laser/desorption ionization (AP-MALDI)
Laser wavelength
355 nm (Nd:YAG DPSS laser)
Laser repetition rate
1-10 kHz
Laser energy
<3 J/pulse
Minimum laser spot size
5-10 micron (UHR model) 50 micron (HR model)
Limit of detection
1 femtomole/sample (Bradykinin) (typically)
Mass range
According to that of  mass spectrometer
Sample plate formats
Opti-TOF (192 spots), 25-mm wide microscope slides
X stage travel distance
55 mm
Y stage travel distance
40 mm
Accuracy of X-Y stages
5 micron ( UHR model) 10 micron (HR model)
Modes of operation
Manual/Automated for multiple spots, Pattern for MS imaging
Sample monitoring
CCD camera
Interchangeability
Interchangeable with ESI, APCI and other sources within minutes
Synchronization
Contact Closure cable
Control software platform
Windows 7/8/10
Control Interface
Ethernet RJ-45 or USB
Dimensions
33cm(L)x17cm(H)x18cm(W)
Weight
6 kg
Power
95-240 VAC, 80 W

Features

  • All solid-state 10 KHz Nd-YAG laser for longer lifetime and stability
  • Spot sizes of 5 - 10 micron
  • Switch from ESI to AP-MALDI in less than 1 minute
  • Click and point software for simple acquisition
  • Images produced compare with the quality of data from expensive dedicated MALDI mass spectrometers
Tomato1
Tomato2
Tomato3

Request a quote

Complete our Request a Quote form, and we will promptly prepare a tailored quote designed to meet your requirements. We’re here to support your purchase. Please submit your details, and we’ll respond with a tailored quote.

Alternatively, you can telephone us directly during business hours or drop us an email.

+44 (0) 1270 763471

Applications and Data Examples

Maldi Imaging

Add AP-MALDI to your LC-MS instrument and preform Mass Spec Imaging (MSI) at a fraction of the cost of a dedicated MALDI Mass Spectrometer. The MassTech AP-MALDI source can be added to ThermoFisher Scientific, Agilent, AB-Sciex LC-MS instruments to give you MALDI imaging capability.

Tissue Imaging

The data shown below was produced using an AP‑MALDI UHR / Orbitrap Exploris 480 HRMS imaging experiment performed by Dr. Gilles Frache, Luxembourg Institute of Science and Technology (LIST) and Maureen Feucherolles ( LIST). The mouse brain was obtained through the courtesy of Pr. William J Griffiths Pr. Yuqin Wang (Swansea University Oxysterol Research Group) and the cryo-sections have been prepared for analysis using the SunChrom matrix sprayer. The tissue was imaged at 25 micrometer pixel size at a mass resolution of 480 000 at m/z 200.

Lipids in mouse brain. Data achieved on Exploris 480 at 20 micron lateral resolution. Data courtesy of Dr. Gilles Frache Luxembourg Institute of Science and Technology

The image shows the RGB overlay image of 3 lipids. Red: [C40H79O10P + Na]⁺ m/z=773.5303 tentatively assigned as PG(34:0), Green: [C41H82NO8P + Na]⁺ m/z=770.5670 tentatively assigned as PE(36:0), Blue: [C46H89NO8 + H]⁺ m/z=784.6661 tentatively assigned as GalCer(40:1) according to Metaspace http://www.nature.com/nmeth/journal/v14/n1/full/nmeth.4072.html

The data set is available on https://metaspace2020.eu/datasets?prj=f62682cc-5ebd-11ee-adaa-33f255ad8aae

One of the uses of MALDI tissue imaging in the pharmaceutical industry is to monitor the distribution of drugs and their metabolites in target tissues. This interesting application note shows the use of the AP-MALDI source with a high resolution mass spectrometer analysing tissues that have been prepared for analysis using the SunCollect spraying device.

Suncollect Application of Anticancer Drug